{"product_id":"hi-98194-multiparameter-ph-orp-ec-do-waterproof-meter","title":"HI-98194 Multiparameter pH\/ORP\/EC\/DO Waterproof Meter","description":"\u003cp\u003e\u003cspan\u003eThe HI-98194 provides multiparameter measurement in a compact and rugged IP67 waterproof \u003c\/span\u003eenclosure. Ideal for demanding applications, this meter features our rugged, quick-connect multi-function probe with field-replaceable sensors. The HI-98194 measures pH\/mV, ORP, Conductivity, TDS, Resistivity, Salinity, Seawater, Dissolved Oxygen, Atmospheric Pressure, and Temperature.\u003c\/p\u003e\n\u003cp\u003eAlso available with 10m, 20m, and 40m cables. See the table below for details. Prices will vary.\u003c\/p\u003e\n\u003cp\u003eA backlit, graphic LCD provides easy-to-read resolution even in low-lit areas. A combination of dedicated and soft keys allows easy, intuitive operation in a choice of languages.\u003c\/p\u003e\n\u003cp\u003eThe HI-98194 allows users to store up to 45,000 continuous or log-on-demand samples with logging intervals from one second to three hours. Logged data can be later transferred to a PC with the HI-920015 micro USB cable and Hanna software.\u003c\/p\u003e\n\u003cp\u003eComprehensive GLP data includes data from the last five calibrations. The contextual Help Menu can be accessed to obtain on-screen information and assistance about each feature at the touch of a button.\u003c\/p\u003e\n\u003cp\u003eThe HI-7698194 probe features a quick-connect DIN connector to make attaching and removing the probe simple and easy.\u003c\/p\u003e\n\u003cp\u003eThe HI-98194 provides multi-parameter measurement in a compact and rugged IP67 waterproof enclosure. Ideal for demanding applications, this meter features our rugged, quick-connect multi-function probe with field-replaceable sensors.\u003c\/p\u003e\n\u003cp\u003eA backlit, graphic LCD provides easy-to-read resolution even in low-lit areas. A combination of dedicated and soft keys allows easy, intuitive operation in a choice of languages.\u003c\/p\u003e\n\u003cp\u003eThe HI-98194 allows users to store up to 45,000 continuous or log-on-demand samples with logging intervals from one second to three hours. Logged data can be later transferred to a PC with the HI-920015 micro USB cable and Hanna software.\u003c\/p\u003e\n\u003cp\u003eComprehensive GLP data includes data from the last five calibrations. The contextual Help Menu can be accessed to obtain on-screen information and assistance about each feature at the touch of a button.\u003c\/p\u003e\n\u003cp\u003eThe HI-7698194 probe features a quick-connect DIN connector to make attaching and removing the probe simple and easy.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eKey features\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\n\u003cli\u003eIP67 rated waterproof, rugged enclosure for the meter, IP68 for the probe\u003c\/li\u003e\n\n\u003cli\u003eColour-coded, field-replaceable sensors\u003c\/li\u003e\n\n\u003cli\u003eAutomatic sensor recognition\u003c\/li\u003e\n\n\u003cli\u003eAutomatic logging of up to 45,000 samples\u003c\/li\u003e\n\n\u003cli\u003eStore measurement data at the press of a button\u003c\/li\u003e\n\n\u003cli\u003eOn-screen, context-specific help is readily available at the press of a button\u003c\/li\u003e\n\n\u003cli\u003ePC connectivity via opto-isolated micro-USB with Hanna software\u003c\/li\u003e\n\n\u003cli\u003eUp to 360 hours of battery life, powered by (4) 1.5V batteries\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003epH specific features\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\n\u003cli\u003e\n\n\u003cul\u003e\n\n\u003cli\u003eUp to three-point calibration with five standard buffers and one custom buffer available\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eEC\/TDS\/Resistivity specific features\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\n\u003cli\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e\n\n\u003cul\u003e\n\n\u003cli\u003eSingle-point calibration from six standards (84 μS\/cm, 1413 μS\/cm, 5.00 mS\/cm, 12.88 mS\/cm, 80 mS\/cm, 111.8 mS\/cm)\u003c\/li\u003e\n\n\u003cli\u003eAutomatic temperature compensation with configurable temperature coefficient range from 0.00 to 6.00%\/°C\u003c\/li\u003e\n\n\u003cli\u003eChoice of reference temperatures at 20 or 25°C\u003c\/li\u003e\n\n\u003cli\u003eAbsolute conductivity can be displayed along with the temperature-compensated value\u003c\/li\u003e\n\n\u003cli\u003eAuto-ranging\u003c\/li\u003e\n\n\u003cli\u003ePractical Salinity Scale (PSU) based on conductivity calibration\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eDissolved Oxygen specific features\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\n\u003cli\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e\n\n\u003cul\u003e\n\n\u003cli\u003eDisplay units in % saturation or mg\/L (ppm)\u003c\/li\u003e\n\n\u003cli\u003eSalinity compensation for concentration\u003c\/li\u003e\n\n\u003cli\u003ePressure compensation for concentration\u003c\/li\u003e\n\n\u003cli\u003eBuilt-in barometer with user-selectable units (mmHg, inHg, atm, psi, kPa, mbar)\u003c\/li\u003e\n\n\u003cli\u003eTemperature compensation\u003c\/li\u003e\n\n\u003cli\u003eAutomatic polarisation of probe at startup\u003c\/li\u003e\n\n\u003cli\u003eReady-to-use HDPE pre-tensioned membrane caps are easy to replace\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch3\u003eColour-Coded, Field-Replaceable Sensors\u003c\/h3\u003e\n\u003cul\u003e\n\n\u003cli\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e\n\n\u003cul\u003e\n\n\u003cli\u003eHI-7698194-0 Double Ceramic Junction pH Sensor\u003c\/li\u003e\n\n\u003cli\u003eHI-7698194-1 pH \u0026amp; platinum ORP Sensor\u003c\/li\u003e\n\n\u003cli\u003eHI-7698194-3 Four-ring, stainless steel conductivity sensor\u003c\/li\u003e\n\n\u003cli\u003eHI-7698194-2 Galvanic dissolved oxygen sensor\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch3\u003eOn-screen features\u003c\/h3\u003e\n\u003ch3\u003eSetup screen\u003c\/h3\u003e\n\u003cp\u003eOur extensive setup screen features a host of configurable options such as time, date, temperature units, and different languages for help screens and guides.\u003c\/p\u003e\n\u003ch3\u003eQuick Calibration\u003c\/h3\u003e\n\u003cp\u003eThe quick calibration feature allows for a single-point calibration for pH, conductivity, and dissolved oxygen, all in a few simple steps.\u003c\/p\u003e\n\u003ch3\u003eProbe Details\u003c\/h3\u003e\n\u003cp\u003eThe HI-7698194 is a multiparameter pH\/EC\/DO\/Temperature probe for use with the HI-98194 portable meter.\u003c\/p\u003e\n\u003cp\u003eIt features a quick-connect that makes a waterproof connection with the meter. Sensors are automatically recognised by the probe and meter when connected.\u003c\/p\u003e\n\u003cp\u003eAny ports not used on the probe will not have the parameter displayed on the meter. Sensor replacement is quick and easy with field-replaceable, screw-type connectors that are colour-coded for easy sensor identification.\u003c\/p\u003e\n\u003cp\u003eThe probe features a multi-strand, multi-conductor shielded cable with 4m, 10m, 20m, and 40m lengths available. Its rugged, waterproof design makes it ideal for field use. IP68 sensor.\u003c\/p\u003e\n\u003ch3\u003eRugged Carrying Case\u003c\/h3\u003e\n\u003cp\u003eThe HI-98194 meter, probe, and all accessories are supplied in a rugged carrying case designed to provide years of use. The inside compartment of the carrying case is thermoformed to securely hold and protect all of the components.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eDIN Connection\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eIP68:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eElectrode is dust-tight and protected against the effects of continuous immersion in water beyond 1m.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable\u003e\n\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003epH\/mV Range\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003e0.00 to 14.00 pH \/ ± 600.0 mV\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eResolution\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003e0.01 pH \/ 0.1 mV\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003e±0.02 pH \/ ±0.5 mV\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003eautomatic one, two, or three points with automatic recognition of five standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) or one custom buffer\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eORP Range\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003e±2000.0 mV\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eORP Resolution\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eORP Accuracy\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003e±1.0 mV\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eORP Calibration\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003eautomatic at one custom point (relative mV)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eEC Range\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003e0 to 200 mS\/cm (absolute EC up to 400 mS\/cm)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eEC Resolution\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003eManual: 1μS\/cm; 0.001 mS\/cm; 0.01 mS\/cm; 0.1 mS\/cm;\u003cspan\u003e \u003c\/span\u003e\u003cb\u003eautomatic\u003c\/b\u003e: 1μS\/cm from 0 to 9999 μS\/cm; 0.01 mS\/cm from 10.00 to 99.99 mS\/cm; 0.1 mS\/cm from 100.0 to 400.0 mS\/cm;\u003cspan\u003e \u003c\/span\u003e\u003cb\u003eautomatic mS\/cm\u003c\/b\u003e: 0.001 mS\/cm from 0.000 to 9.999 mS\/cm; 0.01 mS\/cm from 10.00 to 99.99 mS\/cm; 0.1 mS\/cm from 100.0 to 400.0 mS\/cm\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eEC Accuracy\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003e±1% of reading or ± 1μS\/cm, whichever is greater\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eEC Calibration\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003eautomatic single point, with six standard solutions (84μS\/cm, 1413μS\/cm, 5.00mS\/cm, 12.88 mS\/cm, 80.0 mS\/cm, 111.8 mS\/cm) or custom point\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eTDS Range\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003e0 to 400.0 ppt (g\/L) (the maximum value depends on the TDS factor)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eTDS Resolution\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003e\n\n\u003cb\u003emanual\u003c\/b\u003e: 1 ppm (mg\/L); 0.001 ppt (g\/L); 0.1 ppt (g\/L); 1 ppt (g\/L);\u003cspan\u003e \u003c\/span\u003e\u003cb\u003eautomatic\u003c\/b\u003e: 1ppm (mg\/L) from 0 to 9999 ppm (mg\/L); 0.01 ppt (g\/L) from 10.00 to 99.99 ppt (g\/L); 0.1 ppt (g\/L) from 100.0 to 400.0 ppt (g\/L);\u003cspan\u003e \u003c\/span\u003e\u003cb\u003eautomatic ppt (g\/L):\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e0.001 ppt (g\/L) from 0.000 to 9.999 PPT (g\/L) from 10.00 to 99.99 ppt (g\/L); 0.1 ppt (g\/L) from 100.0 to 400.0 pp (g\/L)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eTDS Accuracy\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003e±1% of reading or ±1 ppm (mg\/L), whichever is greater\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eTDS Calibration\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003ebased on conductivity or salinity calibration\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eResistivity Range\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003e0 to 999999 Ω.cm; 0 to 1000.0 kΩ.cm; 0 to 1.0000 MΩ.cm\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eResistivity Resolution\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003edependent on resistivity reading\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eResistivity Calibration\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003ebased on conductivity or salinity calibration\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eSalinity Range\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003e0.00 to 70.00 PSU\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eSalinity Resolution\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003e0.01 PSU\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eSalinity Accuracy\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003e±2% of reading or ±0.01 PSU, whichever is greater\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eSalinity Calibration\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003ebased on conductivity calibration\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eSeawater σ Range\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003e0.0 to 50.0 σt, σ\u003csub\u003e0\u003c\/sub\u003e, σ\u003csub\u003e15\u003c\/sub\u003e\n\n\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eSeawater σ Resolution\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003e0.1 σ t, σ\u003csub\u003e0\u003c\/sub\u003e, σ\u003csub\u003e15\u003c\/sub\u003e\n\n\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eSeawater σ Accuracy\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003e±1 σ t, σ\u003csub\u003e0\u003c\/sub\u003e, σ\u003csub\u003e15\u003c\/sub\u003e\n\n\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eSeawater σ Calibration\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003ebased on conductivity or salinity calibration\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eDissolved Oxygen Range\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003e0.0 to 500.0%, 0.00 to 50.00 ppm\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eDO Resolution\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003e0.1%; 0.01 ppm (mg\/L)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eDO Accuracy\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003e0.0 to 300.0%; ±1.5% of reading or ±1.0%, whichever is greater; 300.0 to 500.0%; ±3% of reading; 0.00 to 30.00 ppm (mg\/L); ±1.5% of reading or ±0.10 ppm (mg\/L), whichever is greater; 30.00 ppm (mg\/L) to 50.00 ppm (mg\/L); ±3% of reading\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eDO Calibration\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003eautomatic one or two points at 0.100% or one custom point\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eAtmospheric Pressure Range\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003e450 to 850 mm Hg; 17.72 to 33.46 in Hg; 600.0 to 1133.2 mbar; 8.702 to 16.436 psi; 0.5921 to 1.1184 atm; 60.00 to 113.32 kPa\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eAtmospheric Pressure Resolution\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003e0.1 mm Hg; 0.01 in Hg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eAtmospheric Pressure Accuracy\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003e±3mm Hg within ±15°C from the temperature during calibration\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eAtmospheric Pressure Calibration\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003eautomatic at one custom point\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003e-5.00 to 55.00°C\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003e0.01°C\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003e±0.15°C\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eTemperature Calibration\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003eAutomatic at one custom point\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eAdditional Specifications\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e Maximum probe immersion\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003eDepth - 20 metres\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e  Temperature compensation\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003eautomatic from -5 to 55°C\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e  Logging Memory\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003e45,000 records (continuous logging or log-on-demand of all parameters)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e  Logging Interval\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003eone second to three hours\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e PC Connectivity\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003evia USB (with Hanna PC software)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e  Environment\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003e0 to 50°C; RH 100% IP67\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e  Battery Type\/Life\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003e1.5V AA batteries (4) \/ approximately 360 hours of continuous use without backlight (50 hours with backlight)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e  Dimensions\/Weight\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003e185 x 93 x 35.2 mm \/ 400g\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eOrdering information:\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003eThe HI-98194 is supplied with the HI-7698194 probe, HI-7698194-1 pH\/ORP sensor, HI-7698194-3 EC sensor, HI-7698194-2 DO sensor, HI-76981942 probe maintenance kit (HI-7042S DO electrolyte solution, DO membrane caps (5), O-rings for sensors (5), syringe with grease to lubricate the O-rings), HI-9298194 Hanna PC software, HI-920015 micro USB cable, 1.5V AA batteries (4), instruction manual, quick start guide, quality certificate, and rugged carrying case with custom thermo-formed insert.\u003cbr\u003eThe HI-98194 is supplied with an HI-7698194\/4 multiparameter probe with a 4m cable. Also available:\u003cbr\u003eHI-98194\/10 is supplied with an HI-7698194\/10 multiparameter probe with a 10m cable\u003cbr\u003eHI-98194\/20 is supplied with an HI-7698194\/20 multiparameter probe with a 20m cable\u003cbr\u003eHI-98194\/40 is supplied with an HI-7698194\/40 multiparameter probe with a 40m cable\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eAccessories\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003eHI-710034 Orange protective rubber boot\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/tbody\u003e\n\n\n\u003c\/table\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":54497606271299,"sku":"HI-98194","price":2784.95,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0595\/1864\/8365\/files\/1712.webp?v=1779441504","url":"https:\/\/korellifarmi.com\/en\/products\/hi-98194-multiparameter-ph-orp-ec-do-waterproof-meter","provider":"Korallifarmi","version":"1.0","type":"link"}