{"product_id":"hi-98195-multi-parameter-ph-orp-ec-waterproof-meter","title":"HI-98195 Multi-parameter pH \/ ORP \/ EC Waterproof Meter","description":"\u003cp\u003eHI-98195 provides multi-parameter measurement in a compact and rugged IP67 waterproof enclosure. Ideal for demanding applications, this meter features our rugged, quick-connect multi-function probe with field-replaceable sensors.\u003c\/p\u003e\n\u003cp\u003eA backlit, graphic LCD provides easy-to-read resolution even in low-lit areas. A combination of dedicated and soft keys allows for easy, intuitive operation in a choice of languages.\u003c\/p\u003e\n\u003cp\u003eHI-98195 allows users to store up to 45,000 continuous or log-on-demand samples with logging intervals from one second to three hours. Logged data can later be transferred to a PC with the HI-920015 micro USB cable and Hanna software.\u003c\/p\u003e\n\u003cp\u003eComprehensive GLP data includes information from the last five calibrations. The contextual Help Menu can be accessed to obtain on-screen information and assistance regarding each feature at the touch of a button.\u003c\/p\u003e\n\u003ch3\u003epH specific features\u003c\/h3\u003e\n\u003cul\u003e\n\n\u003cli\u003eUp to three-point calibration with five standard buffers and one custom buffer available\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch3\u003eEC\/TDS\/Resistivity specific features\u003c\/h3\u003e\n\u003cul\u003e\n\n\u003cli\u003eSingle-point calibration from six standards (84 µS\/cm, 1413 µS\/cm, 5.00 mS\/cm, 12.88 mS\/cm, 80 mS\/cm, 111.8 mS\/cm)\u003c\/li\u003e\n\n\u003cli\u003eAutomatic temperature compensation with a configurable temperature coefficient range from 0.00 to 6.00%\/°C\u003c\/li\u003e\n\n\u003cli\u003eChoice of reference temperatures at 20 or 25°C\u003c\/li\u003e\n\n\u003cli\u003eAbsolute conductivity can be displayed alongside the temperature-compensated value\u003c\/li\u003e\n\n\u003cli\u003eAuto-ranging\u003c\/li\u003e\n\n\u003cli\u003ePractical Salinity Scale (PSU) based on conductivity calibration\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\n\u003cli\u003eIP67-rated waterproof, rugged enclosure for the meter, IP68 for the probe\u003c\/li\u003e\n\n\u003cli\u003eColor-coded, field-replaceable sensors\u003c\/li\u003e\n\n\u003cli\u003eAutomatic sensor recognition\u003c\/li\u003e\n\n\u003cli\u003eAutomatic logging of up to 45,000 samples\u003c\/li\u003e\n\n\u003cli\u003eStore measurement data at the press of a button\u003c\/li\u003e\n\n\u003cli\u003eOn-screen, context-specific help is readily available at the press of a button\u003c\/li\u003e\n\n\u003cli\u003ePC connectivity via opto-isolated micro-USB with Hanna software\u003c\/li\u003e\n\n\u003cli\u003eUp to 360 hours of battery life, powered by (4) 1.5V batteries\u003c\/li\u003e\n\n\u003cli\u003eThe HI-7698195 probe features a quick-connect DIN connector that creates a waterproof connection with the meter\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003cp\u003eIP68 - The electrode is dust-tight and protected against the effects of continuous immersion in water beyond 1m.\u003c\/p\u003e\n\u003cp\u003ePC Interface - Download test results to a computer programmed with HANNA’s Windows®-compatible software (HI-92000), directly from the equipment via a USB port or an RS232 cable outlet.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable\u003e\n\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003epH\/mV Range\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003e0.00 to 14.00 pH \/ ± 600.0 mV\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eResolution\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003e0.01 pH \/ 0.1 mV\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003e±0.02 pH \/ ±0.5 mV\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003eAutomatic one, two, or three points with automatic recognition of five standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) or one custom buffer\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eORP Range\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003e±2000.0 mV\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eORP Resolution\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eORP Accuracy\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003e±1.0 mV\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eORP Calibration\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003eAutomatic at one custom point (relative mV)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eEC Range\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003e0 to 200 mS\/cm (absolute EC up to 400 mS\/cm)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eEC Resolution\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003eManual: 1 µS\/cm; 0.001 mS\/cm; 0.01 mS\/cm; 0.1 mS\/cm; \u003cb\u003eAutomatic\u003c\/b\u003e: 1 µS\/cm from 0 to 9999 µS\/cm; 0.01 mS\/cm from 10.00 to 99.99 mS\/cm; 0.1 mS\/cm from 100.0 to 400.0 mS\/cm; \u003cb\u003eAutomatic mS\/cm\u003c\/b\u003e: 0.001 mS\/cm from 0.000 to 9.999 mS\/cm; 0.01 mS\/cm from 10.00 to 99.99 mS\/cm; 0.1 mS\/cm from 100.0 to 400.0 mS\/cm\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eEC Accuracy\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003e±1% of reading or ± 1 µS\/cm, whichever is greater\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eEC Calibration\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003eAutomatic single point, with six standard solutions (84 µS\/cm, 1413 µS\/cm, 5.00 mS\/cm, 12.88 mS\/cm, 80.0 mS\/cm, 111.8 mS\/cm) or custom point\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eTDS Range\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003e0 to 400.0 ppt (g\/L) (the maximum value depends on the TDS factor)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eTDS Resolution\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003e\n\u003cb\u003eManual\u003c\/b\u003e: 1 ppm (mg\/L); 0.001 ppt (g\/L); 0.1 ppt (g\/L); 1 ppt (g\/L); \u003cb\u003eAutomatic\u003c\/b\u003e: 1 ppm (mg\/L) from 0 to 9999 ppm (mg\/L); 0.01 ppt (g\/L) from 10.00 to 99.99 ppt (g\/L); 0.1 ppt (g\/L) from 100.0 to 400.0 ppt (g\/L); \u003cb\u003eAutomatic ppt (g\/L):\u003c\/b\u003e 0.001 ppt (g\/L) from 0.000 to 9.999 ppt (g\/L); 0.01 ppt (g\/L) from 10.00 to 99.99 ppt (g\/L); 0.1 ppt (g\/L) from 100.0 to 400.0 ppt (g\/L)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eTDS Accuracy\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003e±1% of reading or ±1 ppm (mg\/L), whichever is greater\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eTDS Calibration\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003eBased on conductivity or salinity calibration\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eResistivity Range\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003e0 to 999999 Ω·cm; 0 to 1000.0 kΩ·cm; 0 to 1.0000 MΩ·cm\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eResistivity Resolution\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003eDependent on resistivity reading\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eResistivity Calibration\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003eBased on conductivity or salinity calibration\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eSalinity Range\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003e0.00 to 70.00 PSU\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eSalinity Resolution\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003e0.01 PSU\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eSalinity Accuracy\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003e±2% of reading or ±0.01 PSU, whichever is greater\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eSalinity Calibration\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003eBased on conductivity calibration\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eSeawater σ Range\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003e0.0 to 50.0 σt, σ\u003csub\u003e0\u003c\/sub\u003e, σ\u003csub\u003e15\u003c\/sub\u003e\n\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eSeawater σ Resolution\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003e0.1 σt, σ\u003csub\u003e0\u003c\/sub\u003e, σ\u003csub\u003e15\u003c\/sub\u003e\n\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eSeawater σ Accuracy\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003e±1 σt, σ\u003csub\u003e0\u003c\/sub\u003e, σ\u003csub\u003e15\u003c\/sub\u003e\n\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eSeawater σ Calibration\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003eBased on conductivity or salinity calibration\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003e-5.00 to 55.00°C\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003e0.01°C\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003e±0.15°C\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eTemperature Calibration\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003eAutomatic at one custom point\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eAdditional Specifications\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e  Maximum probe immersion\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003eDepth - 20 meters\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e   Temperature compensation\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003eAutomatic from -5 to 55°C\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e   Logging Memory\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003e45,000 records (continuous logging or log-on-demand of all parameters)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e   Logging Interval\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003eOne second to three hours\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e  PC Connectivity\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003eVia USB (with Hanna PC software)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e   Environment\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003e0 to 50°C; RH 100% IP67\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e   Battery Type\/Life\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003e1.5V AA batteries (4) \/ approximately 360 hours of continuous use without backlight (50 hours with backlight)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e   Dimensions\/Weight\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003e185 x 93 x 35.2 mm \/ 400g\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eOrdering information:\u003c\/td\u003e\n\n\u003ctd\u003e\u003c\/td\u003e\n\n\u003ctd\u003eHI-98195 is supplied with HI-7698195\/4 multiparameter probe, HI-7698194-1 pH\/ORP sensor, HI-7698194-3 EC sensor, HI-9828-20 quick calibration solution, HI-76981952 probe maintenance kit, HI-76981943 calibration beaker, HI-9298194 Hanna PC software, HI-920015 micro USB cable, 1.5V AA batteries (4), instruction manual, quick start guide, quality certificate, and rugged carrying case with custom insert.\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/tbody\u003e\n\n\n\u003c\/table\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":54497608106307,"sku":"HI-98195","price":1684.95,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0595\/1864\/8365\/files\/1711.webp?v=1779441733","url":"https:\/\/korellifarmi.com\/en\/products\/hi-98195-multi-parameter-ph-orp-ec-waterproof-meter","provider":"Korallifarmi","version":"1.0","type":"link"}